Chromatography
HPLC - High Pressure Liquid Chromatography
HPLC System
LabAlliance UHP HPLC System
LabAlliance raised the pressure bar for ultra high pressure HPLC (UHPLC) from 3000 psi to 18000 psi with the introduction of a new modular chromatograph. The LabAlliance UHP HPLC System or the LabAlliance Ultra High Pressure HPLC System cost approximately 20 percent less than any other system on the market AND offers equal or better performance. Such performance is WITHOUT precedence in the market. The performance and savings in time and money spent on solvent is without parallel. Gradient elution is provided by two pumps and a high pressure mixer. LabAlliance is legendary for pump engineering -provable performance equivalent or superior to any pump on the HPLC market- and straightforward design. Their pumps probably have a serviceable life of several decades!
These pumps can deliver mobile phase at 0.001 to 5mL per min at 18000 psi! A market first!
One of the most interesting design challenges was to reduce the pressure ripple and maintain the flow rate. For some solvents especially organics the compressibility is so high that about half of the displacement stroke is used up in compression! LabAlliance solves the hurdle with active control algorithms to balance this requirement. Pressure recordings show that pressure ripple at 15794 psi is about 10 psi. The spec is less than 1.5 percent or about 220 psi. Astounding! Flow rate accuracy at 10000 psi is within 1 % and precision is better than +/- 0.5% At LabAlliance....mission accomplished!
LabAlliance HPLC with 20 Hz Data Collection for Fast Chromatography
The standard detector gives 20 Hz resolution to allow peaks of .2sec to be accurately measured. The system can be ordered with a high speed 80 Hz diode array or fluorescence detector. Compare this to the competition and you will find the LabAlliance UHPLC solution better
With a High Speed Autosampler for Fast Analysis the UHP Autosampler gives injections as quick as 15 seconds and allows for full loop- partial loop and a ?l pickup mode for valuable samples.
Additional Options Metal-free sampling with silica-coated steel needle and PEEK valve HPLC version available /Reagent addition and mix / 6-port solvent selection valve for reagent addition and extensive needle wash (option) / Quick-fit injection valve for fast.
| Pump | |
| Flow Rates | 0.001-5.000 mL/min |
| Pressure | 0-18000 psi |
| Pulsation | -/+ 1 percent @ 1mL/min and 1000 psi |
| Pressure Accuracy | -/+ 1 percent of full scale |
| Flow Accuracy | -/+ 2 percent |
| Flow Precision | 0.2 percent |
| Gradient Accuracy | Within 1 percent absolute at 1mL/min and 10000 psi |
| Voltage | 110-120 V or 240-240 V at 50/60 Hz |
| Dimmensions (H x W x D) | 6.5 x 12 x 15.5 inch |
| Auto Sampler | |
| Pan Size (inch) | 6.5 x 6.5 |
| Response Time | 2-3 sec |
| Calibration | Auto External |
| Unit of Measure | g/mg/ct/GN/mo/oz/dwt |
| Tare Range | Full |
| Operating Tempeature | 15-35C |
| Dimmensions (W x D x H) | 8.2 x 11.8 x 3.5 inch |
| Weight | 8.8 Ilbs |
| Voltage of Power Supply | AC 230 |
| Pump Specification | |
| Injection Range | 1 ul- 1ul increment 500 ul syringe UHP model has 100 ul loop |
| Sample capacity | 2 well plates 96 or 384 (deep or shallow); 96 vials (1.5 ml); Option: 24 vials (10 ml) |
| Injection precision | RSD for injection volume > 10 ?l Full-loop: 0.3%; Partial-loop: 0.5%; ?l-pick-up: 1.0% |
| Carry-over | Gas flush-out characteristic for a non sticking compound < 0.05% (Uracil in water; with 300 ul wash) |
| Needle wash | 1 solvent; programmable volume; wash reservoir: 250 ml Option: 6 wash solvents |
| Cycle time | < 1 min- including 300 ?l wash |
| Sample cooling (option) | 4C +/- 2C (at max ambient temp of 25 C) |
| Injection Cycle Time | 10-15 sec |
| Maximum System Pressures | 18-000psi |
| Sampling technology | Air - pressure assisted sample aspiration; No sample-syringe contact Fixed concentric air/sample needle pair |