Tosoh AIA-360 Immunoassay Analyzer

  • Any test, any time, any combination
  • Continuous loading of samples
  • 36 Tests per hour
  • Quick calibration curve reporting
  • Built in level sensor eliminates short sampling
... Full Description >>>


Complete Product Description

Tosoh AIA-360 Immunoassay Analyzer Offers the automation powers and performance of a large analyzer in a bench top format. Random access allows any combination of tests, in any order at any time and a throughput of 36 results per hour with the first result in 20 minutes ensures a fast reliable service. This instrument is absolutely perfect for the physician office laboratory (POL) or small hospital clinic setting.

Tosoh AIA-360 Immunoassay Analyzer Features

  • any test, any time, any combination
  • Continuous loading of samples
  • 36 tests per hour
  • Utilizes Tosoh's standardized Unit Dose Test Cup reagent format
  • quick calibration curve reporting
  • built in level sensor eliminates short sampling
  • sample probe eliminates carryover
  • LOW maintenance=high uptime

Assay methodology is one-step sandwich and competitive EIA at 37C. Mixing by magnetic agitation. Top to top fluorescent multichannel light source. Excitation wavelength 325-385nm, emission wavelength 440-500nm.

AIA-Pack Test Cup
At the heart of all Tosoh AIA systems is the patented AIA Pack Unit Dose Test Cup reagent system. Single, unitized cups require no pre-mixing, no pre-measuring, no on-board refrigeration and no waste.

One Reagent for all Tosoh AIA Systems
Tosoh's patented Unit Dose Test Cup technology provides consistency and interchangeability of reagents for Tosoh's Automated Immunoassay Systems: AIA-1800, AIA-600 II and AIA-360.

  • Full test menu
  • Single, unitized cups require no pre-mixing, no pre-measuring, no on-board refrigeration and no waste.
  • Dry reagent format ensures 60 to 90 day calibration stability for most assays.
  • Bar-coded for easy test identification and inventory management.
  • Most reagents have a one year shelf life from date of manufacture.

Tosoh AIA-360 Immunoassay Analyzer Full Test Menu

Thyroid

  • TSH
  • TT3
  • T4
  • FT3
  • FT4
  • T-Uptake
  • *TSH 3rd Gen
  • *TPO Ab
  • *Tg Ab

Cardiac Markers

  • CKMB
  • Troponin I 2nd Gen
  • Myoglobin

Reproductive

  • beta-HCG
  • Estradiol
  • FSH
  • LH II
  • Prolactin
  • Progesterone
  • Testosterone

Tumor Markers

  • AFP
  • CEA
  • PSA
  • CA 125
  • 27.29
  • CA 19-9

Anemia

  • Ferritin
  • *Vitamin B12
  • *Folate

Metabolic

  • Cortisol
  • C-Peptide
  • HGH
  • Insulin
  • iPTH

Other

  • beta-2 Microglobulin
  • IgE II
  • PAP

*Available on AIA-1800 and AIA-600 II only